SETUP
Table 9. Ramp/Soak Profile Setup Menu
Step Step Description
Top
Display
7.10.2
Segment 10 End Value.
UP
or
DN
sets value.
SCRL
to advance to:
Step 7.10.3 if start and end values are the same,
or
Step 7.10.4 if start and end values are different.
SEG 10
7.10.3
Segment 10 Soak Time.
UP
or
DN
sets time.
SCRL
to advance to:
Step 7.10.5 if relay A is set for ramp/soak (in
Relays), or
Step 7.10.6 if relay B is set for ramp/soak, or
Step 7.10.7 if relay C is set for ramp/soak, or
Step 7.10.8 otherwise.
SEG 10
7.10.4
Segment 10 Ramp Rate.
UP
or
DN
sets rate.
SCRL
to advance to:
Step 7.10.5 if relay A is set for ramp/soak (in
Relays), or
Step 7.10.6 if relay B is set for ramp/soak, or
Step 7.10.7 if relay C is set for ramp/soak, or
Step 7.10.8 otherwise.
SEG 10
7.10.5
Segment 10 Relay A State.
UP
or
DN
selects ON or OFF.
SCRL
to advance to:
Step 7.10.6 if relay B is set for ramp/soak, or
Step 7.10.7 if relay C is set for ramp/soak, or
Step 7.10.8 otherwise.
SEG 10
7.10.6
Segment 10 Relay B State.
UP
or
DN
selects ON or OFF.
SCRL
to advance to:
Step 7.10.7 if relay C is set for ramp/soak, or
Step 7.10.8 otherwise.
SEG 10
100