MODCELL 2050R User’s Guide Indicating Process Controller 2050R Model B Version 2.8 2051R Model B Version 2.8

Pagina 2 - MicroMod Automation, Inc

IB-23C650INTRODUCTIONBlank Page4

Pagina 3 - CONTENTS

IB-23C650SETUPTable 9. Ramp/Soak Profile Setup MenuStep Step DescriptionTopDisplay1Ramp/Soak Menu.UP moves to SETPTS **MENU**.DN moves to TOTALIZE **M

Pagina 4 - CONTENTS (Cont’d)

IB-23C650SETUPTable 9. Ramp/Soak Profile Setup MenuMiddleDisplayBottomDisplayEntry Description**MENU**None.REPEAT NOYES= Stops ramp/soak cycle after l

Pagina 5 - ILLUSTRATIONS

IB-23C650SETUPTable 9. Ramp/Soak Profile Setup MenuStep Step DescriptionTopDisplay7.1.1Segment 1 Start Value.UP or DN sets value.SCRL to advance to St

Pagina 6 - ILLUSTRATIONS (Cont’d)

IB-23C650SETUPTable 9. Ramp/Soak Profile Setup MenuMiddleDisplayBottomDisplayEntry DescriptionSTART SP xxxxBetween ‘Local Set-point Low Limit’ and ‘Lo

Pagina 7

IB-23C650SETUPTable 9. Ramp/Soak Profile Setup MenuStep Step DescriptionTopDisplay7.1.5Segment 1 Relay A State.UP or DN selects ON or OFF.SCRL to adva

Pagina 8 - IDENTIFICATION INFORMATION

IB-23C650SETUPTable 9. Ramp/Soak Profile Setup MenuMiddleDisplayBottomDisplayEntry DescriptionRELAY A ONOFFState of the relay during segment.RELAY B O

Pagina 9

IB-23C650SETUPTable 9. Ramp/Soak Profile Setup MenuStep Step DescriptionTopDisplay7.10.2Segment 10 End Value.UP or DN sets value.SCRL to advance to:St

Pagina 10 - INTRODUCTION

IB-23C650SETUPTable 9. Ramp/Soak Profile Setup MenuMiddleDisplayBottomDisplayEntry DescriptionEND SP xxxxBetween ‘Local Set-point Low Limit’ and ‘Loca

Pagina 11 - INSTALLATION

IB-23C650SETUPTable 9. Ramp/Soak Profile Setup MenuStep Step DescriptionTopDisplay7.10.7Segment 10 Relay C State.UP or DN selects ON or OFF.SCRL to ad

Pagina 12

IB-23C650SETUPTable 9. Ramp/Soak Profile Setup MenuMiddleDisplayBottomDisplayEntry DescriptionRELAY C ONOFFState of the relay during segment.GUARANTD

Pagina 13 - MOUNTING

IB-23C650INSTALLATIONINSTALLATIONGENERALRead these instructions thoroughly before starting installation. Installationpersonnel should be qualified te

Pagina 14 - WIRING GUIDELINES

IB-23C650SETUPTable 10. Integrator/Totalizer MenuStep Step DescriptionTopDisplay1Totalizer Menu.UP moves to RAMPSOAK **MENU** if ramp/soakis enabled,

Pagina 15 - S-3017-7A(3)

IB-23C650SETUPTable 10. Integrator/Totalizer MenuMiddleDisplayBottomDisplayEntry Description**MENU**None.PRED CNT NOYES= Counts until turned off or un

Pagina 16 - POWER CONNECTIONS

IB-23C650SETUPTable 10. Integrator/Totalizer MenuStep Step DescriptionTopDisplay7Totalizer Scale Decimal Point.UP or DN sets decimal point.SCRL to adv

Pagina 17 - Electrical Noise

IB-23C650SETUPTable 10. Integrator/Totalizer MenuMiddleDisplayBottomDisplayEntry DescriptionDEC PT0.0.00.000.000Sets decimal location for scale factor

Pagina 18 - REMOTE SET-POINT CONNECTIONS

IB-23C650SETUPTable 11. Alarm Settings MenuStep Step DescriptionTopDisplay1Alarms Menu.UP moves to TOTALIZE **MENU** if totalizer is enabled, or to RA

Pagina 19

IB-23C650SETUPTable 11. Alarm Settings MenuMiddleDisplayBottomDisplayEntry Description**MENU**None.OCCUR OF NONEDGP1DG, P1P2DG, P2P1, P2DG,P1,P2= Beep

Pagina 20

IB-23C650SETUPTable 11. Alarm Settings MenuStep Step DescriptionTopDisplay5Priority 1 Relay Action. UP or DN selects action.SCRL to advance to:Step 6

Pagina 21 - RTD INPUT

IB-23C650SETUPTable 11. Alarm Settings MenuMiddleDisplayBottomDisplayEntry DescriptionACTION LATCHINGNO LATCH= Relay assigned to alarm will trip (deen

Pagina 22

IB-23C650SETUPTable 11. Alarm Settings MenuStep Step DescriptionTopDisplay7.1.3Alarm 1 Priority.UP or DN selects 1 or 2.SCRL to advance to Step 7.1.4.

Pagina 23

IB-23C650SETUPTable 11. Alarm Settings MenuMiddleDisplayBottomDisplayEntry DescriptionPRIORITY 21= Lower priority= Higher priorityHYST xxxx 0 to 1000,

Pagina 24 - VOLT INPUT

IB-23C650 INTRODUCTION 6 Notes: 1. When mounting housing in panel cutout or rack and panel mounting bezel, turn retaining screws until point of

Pagina 25 - MILLIVOLT INPUT

IB-23C650SETUPTable 12. Tune MenuStep Step DescriptionTopDisplay1Tune Menu.UP moves to ALARMS **MENU**.DN moves to DISPLAYS **MENU**.SCRL to begin set

Pagina 26 - DIGITAL INPUT

IB-23C650SETUPTable 12. Tune MenuMiddleDisplayBottomDisplayEntry Description**MENU**None.NAME xxxxxxxx x= any of the following characters:Letters ‘A’

Pagina 27 - No External Parts: 500 ohms

IB-23C650SETUPTable 12. Tune MenuStep Step DescriptionTopDisplay7Reset Enable.UP selects YES or DN selects NO.SCRL to advance to:Step 7.1 from YES if

Pagina 28 - OUTPUT SIGNAL CONNECTIONS

IB-23C650SETUPTable 12. Tune MenuMiddleDisplayBottomDisplayEntry DescriptionENABLE YESNO= Enable integral response= Don’t enable integral response HEA

Pagina 29

IB-23C650SETUPTable 12. Tune MenuStep Step DescriptionTopDisplay8(cont’d)Preact Value.Step 13 if A/M ratio bias is not enabled and output type is POS

Pagina 30 - Maximum Value: 400 ohms

IB-23C650SETUPTable 12. Tune MenuMiddleDisplayBottomDisplayEntry DescriptionRATIO xxx.xx-300.00 to 300.00Ratio value applied to remote set-point. If r

Pagina 31

IB-23C650SETUPTable 12. Tune MenuStep Step DescriptionTopDisplay13Position Proportioning Deadband.UP or DN sets value.SCRL to advance to Step 14.POS P

Pagina 32 - Blank Page

IB-23C650SETUPTable 12. Tune MenuMiddleDisplayBottomDisplayEntry DescriptionDEADBAND xx.x0.0 to 50.0%Percent difference in calculated output andvalve

Pagina 33 - GENERAL PREPARATIONS

IB-23C650SETUPBlank Page122

Pagina 34 - DATA BASE REFERENCE TABLES

IB-23C650BASIC OPERATIONBASIC OPERATIONINTRODUCTIONOperator activities related to ongoing operations are performed in theDISPLAYS MENU. Some operator

Pagina 35

IB-23C650INSTALLATIONMOUNTINGThe controller must be installed in an approved enclosure or installed in ameans acceptable to the authority having juris

Pagina 36

IB-23C650 INTRODUCTION 124 Alarm Light Alarm Scroll Key Loop Tag Display Tag Key Process Variable Display Manual Key Auto Key Status Dis

Pagina 37

IB-23C650BASIC OPERATIONCONTROL KEYSThe operator control keys are:Alarm: Press to stop flashing and beeping alarm indication.Press repeatedly to view

Pagina 38

IB-23C650BASIC OPERATIONUp (UP): Used in the configuration mode to answer promptsby toggling between YES and NO or other option,and to increment value

Pagina 39

IB-23C650BASIC OPERATIONBottom: Lower EngineeringDisplayIndicates engineering unitvalues for output,set-point,ratio and bias as indicatedby the third

Pagina 40

IB-23C650BASIC OPERATIONMIDDLE DISPLAYRemote: Set-point is derived from a remote location andis brought into the instrument through theremote set-poin

Pagina 41

IB-23C650BASIC OPERATIONTotalize: The totalized count is being displayed in thelower engineering display. See operation ofTotalizer.Autotune: Autotu

Pagina 42

IB-23C650BASIC OPERATIONBAR GRAPHSThree 50-segment bar graphs provide visual indication of process, set-pointand either output or deviation.Process Va

Pagina 43

IB-23C650BASIC OPERATIONRESTARTPower up mode, set-point and output conditions can be defined so that at aninstrument power up condition the controller

Pagina 44

IB-23C650BASIC OPERATIONOPERATION IN AUTOMATIC MODEThis section describes operations for local set-points, remote or multiple set-points, and A/M rati

Pagina 45

IB-23C650BASIC OPERATIONAutomatic Operation with Remote or Multiple Set-PointsThe controller may be in either auto or manual as selected in the power

Pagina 46

IB-23C650INSTALLATIONWIRING GUIDELINESThe power wiring connections and input/output (I/O) connections are madewith the controller installed in its ope

Pagina 47

IB-23C650BASIC OPERATIONTo perform a set-point bumpless transfer, complete the following steps:1) With set-point displayed, press theR/L key to advan

Pagina 48

IB-23C650BASIC OPERATIONAutomatic Operation with A/M Ratio BiasIf ratio, bias or ratio/bias was enabled in the RAT BIAS MENU, the instrumentdisplay wi

Pagina 49

IB-23C650BASIC OPERATIONAUTO/MANUAL TRANSFERTransfer from auto to manual is accomplished by pressing the manual key.Either of the digital inputs may b

Pagina 50

IB-23C650BASIC OPERATIONAuto/Manual Transfer for On-Off ControlIf the controller is set up for on-off control, the bumpless transfer feature doesnot a

Pagina 51

IB-23C650BASIC OPERATIONOPERATION IN MANUALThis section describes operations for local set-points, remote or multiple set-points, and A/M ratio bias w

Pagina 52

IB-23C650BASIC OPERATIONWhen the controller is set up for on/off control, the manual output is a timeproportioning signal. This gives the output infi

Pagina 53

IB-23C650BASIC OPERATIONPress the scroll key to display theoutput in percent in the lowerengineering display.[OUT] appears in the third statusdisplay.

Pagina 54 - to advance to Step 3.5

IB-23C650BASIC OPERATIONUse the following steps to prepare to switch from a local to a remote set-point:1) Press the R/L key until [REM] isdisplayed

Pagina 55 - Table 2. Input Setup Menu

IB-23C650BASIC OPERATIONManual Operation with A/M Ratio BiasIf ratio, bias, or ratio/bias was enabled in the RAT BIAS MENU, the instrumentdisplay will

Pagina 56

IB-23C650BASIC OPERATIONOPERATION USING DIGITAL INPUTSDigital inputs 1 and 2 can be used to control auto/manual transfer,acknowledge alarms, start tot

Pagina 57

IB-23C650INSTALLATIONFigure 2. Controller Power and Signal TerminationsTX PowerVolt InputRTD SrcmA Inpt +Input –mA OutputCOMTX Power 2Volt Input 2RT

Pagina 58

IB-23C650BASIC OPERATIONIf the digital input action is configured to be REVERSE, a closed contact willbe treated as an open contact and vice versa.Not

Pagina 59

IB-23C650BASIC OPERATION2. Select whether to lock out the front panel from making set-point transfers,whether transitions are allowed between local an

Pagina 60 - to advance to Step 4.7

IB-23C650BASIC OPERATIONA transition in the state of either digital input (opened to closed, or closed toopened) will now cause a set-point transfer.

Pagina 61

IB-23C650BASIC OPERATIONcombination of the four display alarms. Monitoring and acknowledging alarmsare basic operator activities. Acknowledgment of

Pagina 62

IB-23C650BASIC OPERATIONFigure 16b. Controller Alarm Display and Relay Status Conditions (Sheet 2)Alarm Ceases beforeACKALARM AND RELAY STATUS WITH A

Pagina 63

IB-23C650BASIC OPERATIONAlarm MessagesAn alarm is active when the process input (PROC), input 2 (INP2), controloutput (OUT), or deviation value (DEV)

Pagina 64

IB-23C650BASIC OPERATIONWhen the alarm finally stops, the alarm indicator will go out. If there is analarm at one limit that has not been acknowledge

Pagina 65

IB-23C650BASIC OPERATIONSTARTUPProcedures may vary from application to application, depending uponindividual requirements and controller setup. The i

Pagina 66

IB-23C650BASIC OPERATION4. Manually adjust output of controller to bring process variable up to finalvalue. Ramping the output should be slow enough

Pagina 67

IB-23C650TUNINGTUNINGMANUAL TUNINGThe controller response parameters: Gain (P), Integral (I), and Derivative (D)are adjustable over a wide range of v

Pagina 68

IB-23C650INSTALLATIONPOWER CONNECTIONSWARNINGAvoid electrical shock. AC power wiring must not beconnected at the distribution panel (ac source) until

Pagina 69

IB-23C650TUNINGTuning ProcedureThe following procedure for tuning a controller is applicable to controllers setup for P (gain), PI (gain plus integral

Pagina 70

IB-23C650TUNINGFigure 17. Process Recovery Cycle with OptimumResponse SettingsIncreasing the gain setting increases cycle B relative to cycle A. If

Pagina 71

IB-23C650TUNINGb. Controller with P and D responses:D = P (Minutes)8c. Controller with P, I, and D responses:I = 1.5P (Minutes)D = P (Minutes)69. Acce

Pagina 72

IB-23C650TUNINGAUTOMATIC TUNINGAutomatic tuning (autotune) is an on-demand user activated feature whichautomatically calculates either PI or PID respo

Pagina 73

IB-23C650TUNINGTable 13. Autotune ProcedureStep Step DescriptionTopDisplay1Displays Menu.UP moves to TUNE **MENU**.DN moves to BASE CFG **MENU**.SCRL

Pagina 74

IB-23C650TUNINGTable 13. Autotune ProcedureMiddleDisplayBottomDisplayEntry Description**MENU**Installation and Setup Check. Installation,and Setup mu

Pagina 75

IB-23C650TUNINGTable 13. Autotune ProcedureStep Step DescriptionTopDisplay4Autotune Activation. UP enters autotune setup.SCRL to return to Step 2.TAG

Pagina 76

IB-23C650TUNINGTable 13. Autotune ProcedureMiddleDisplayBottomDisplayEntry DescriptionxxxProcessValueATN is displayed to indicate the Autotunepoint o

Pagina 77

IB-23C650TUNINGTable 13. Autotune ProcedureStep Step DescriptionTopDisplay7Process High Trip-Point. UP or DN adjusts process high trip-point value.SCR

Pagina 78

IB-23C650TUNINGTable 13. Autotune ProcedureMiddleDisplayBottomDisplayEntry DescriptionPROC HI 100Valid values are: -2997 or PROC LO+3 to 30000.Rememb

Pagina 79 - (i. e. ,100% = 20 mA dc)

IB-23C650INSTALLATIONGROUND CONNECTIONSThe primary power ground system consists of the plant electrical ground(equipment grounding conductors). AC gr

Pagina 80

IB-23C650TUNINGTable 13. Autotune ProcedureStep Step DescriptionTopDisplay11.1Increase Step. SCRL to Step 11.2 for a response limitedmessage.Otherwis

Pagina 81

IB-23C650TUNINGTable 13. Autotune ProcedureMiddleDisplayBottomDisplayEntry DescriptionINCREASE STEP SIZThe ratio of process oscillation to hysteresisv

Pagina 82

IB-23C650TUNINGAutotune CompletionAutotune will generally result in successful calculation of tuning constants.When a completely successful autotune c

Pagina 83

IB-23C650TUNINGCancellation During ExecutionPress the manual key to cancel the autotune cycle during execution by thecontroller. This will prevent co

Pagina 84

IB-23C650TUNINGBlank Page168

Pagina 85

IB-23C650RAMP/SOAK OPERATIONRAMP/SOAK OPERATIONDESCRIPTION OF RAMP/SOAK PROFILEThe Ramp/Soak Profile option complements any type of controlimplementat

Pagina 86 - Table 6. RS-485 Setup Menu

IB-23C650RAMP/SOAK OPERATIONFigure 19. Typical Six-Segment Ramp/Soak Profile170

Pagina 87

IB-23C650RAMP/SOAK OPERATIONOPERATION IN AUTOMATICThe ramp/soak sequence is initiated and monitored in the DISPLAYS MENUwhere the instrument display a

Pagina 88

IB-23C650RAMP/SOAK OPERATIONAfter selecting RUN or HOLD at the beginning of the ramp/soak displaysequence, scrolling accesses the segment status displ

Pagina 89

IB-23C650RAMP/SOAK OPERATIONIf the [SKIP] or [RESET] prompts do not appear, a password has beenconfigured in the BASE CFG MENU and is required to acce

Pagina 90

IB-23C650INSTALLATIONThe combination device suppresses transients and effectively reducesother noise forms such as electromagnetic (EMI) and radio fre

Pagina 91

IB-23C650RAMP/SOAK OPERATION• If the skipped segment is the last segment in the profile and the cycle isconfigured to repeat, the skip returns the pro

Pagina 92

IB-23C650RAMP/SOAK OPERATIONRamp or Soak HysteresisThe hysteresis function provides for setting up a band of process variablevalues relative to the se

Pagina 93 - Table 8. Set-Point Setup Menu

IB-23C650RAMP/SOAK OPERATIONmanual set-point is not at the same value as the ramp/soak profile set-point(the ramp/soak profile is paused at its curren

Pagina 94

IB-23C650TOTALIZER OPERATIONTOTALIZER OPERATIONDESCRIPTION OF INTEGRATION/TOTALIZATION FUNCTIONThe integrator/totalizer provides the capability to int

Pagina 95

IB-23C650TOTALIZER OPERATION• Scale FactorThis feature allows custom scaling of the totalized value. The reciprocalof the entered value (0.001 to 300

Pagina 96

IB-23C650TOTALIZER OPERATIONPreset ValueThe preset value is the number from which the totalizer starts counting after awrap or when the totalizer was

Pagina 97

IB-23C650TOTALIZER OPERATIONEXAMPLES OF TOTALIZER COUNT FACTORSThere are three configurable factors that affect what one totalized count equalsin actu

Pagina 98 - to return to Step 1

IB-23C650TOTALIZER OPERATION Table 14. Examples of Totalizer Count Factors ActualFlow at100%ConfiguredEngineeringUnits(Note 1)Scale(Disp.Mult.)Confi

Pagina 99

IB-23C650TOTALIZER OPERATION2.) Configured scale factors are 0.001 to 30000. The unscaled total is dividedby the configured scale factor to get the s

Pagina 100

IB-23C650RATIO BIAS CONTROLRATIO BIAS CONTROLRATIO BIAS CONTROLLERRatio bias control systems maintain two or more process variables at apredetermined

Pagina 101

IB-23C650INSTALLATIONPROCESS INPUT SIGNAL CONNECTIONSProcess input connections are shown as follows: • Thermocouple Inputs - see Figure 3• RTD Inputs

Pagina 102

IB-23C650RATIO BIAS CONTROLThe independent (wild) flow changes from time to time, and in order tomaintain the correct proportions of the blend the oth

Pagina 103

IB-23C650RATIO BIAS CONTROLcorrect ratio value. When the streams do not have the same flow range, thevariables must be expressed in engineering units

Pagina 104

IB-23C650RATIO BIAS CONTROLFigure 22. Effect of Ratio Adjustment in an Inverse Ratio Control SystemFigure 23. Effect of Bias Adjustment on a Ratio R

Pagina 105

IB-23C650RATIO BIAS CONTROLA/M RATIO BIAS STATIONThe A/M ratio bias station applies a ratio or bias to the process input. Theoutput of the station is

Pagina 106

IB-23C650RATIO BIAS CONTROLA typical A/M Ratio Station application where a plant master steam flowcontroller provides an input to two boiler masters (

Pagina 107

IB-23C650RATIO BIAS CONTROLInstrument Set-upTo implement an A/M Ratio Bias Station, enter into the BASE CFG **MENU**, Table 1, and enable A/M Ratio Bi

Pagina 108 - to advance to Step 7.10.8

IB-23C650RATIO BIAS CONTROLBlank Page190

Pagina 109 - (Step 3 or 4)

IB-23C650TIME PROPORTIONING CONTROLTIME PROPORTIONING CONTROLDESCRIPTIONTime proportioning control permits PID control to be used in applicationswhere

Pagina 110

IB-23C650TIME PROPORTIONING CONTROLFigure 26. Output Relay Duty Cycle for Time Proportioning ControlPID Output% of SpanCycle Time10 SecondsS-1107-41B

Pagina 111

IB-23C650CURRENT PROPORTIONING CONTROLCURRENT PROPORTIONING CONTROLDESCRIPTIONThe controller provides an adjustable dc current output signal for curre

Pagina 112

MicroMod Automation, Inc. The Company MicroMod Automation is dedicated to improving customer efficiency by providing the most cost-effective, applica

Pagina 113

IB-23C650INSTALLATIONFigure 3. Thermocouple Input ConnectionsGROUNDED++ –THERMOCOUPLE INPUT Twisted or ShieldedPair ThermocoupleWireThermocoupleUNGR

Pagina 114

IB-23C650CURRENT PROPORTIONING CONTROLblank page194

Pagina 115 - Table 11. Alarm Settings Menu

IB-23C650DUAL OUTPUT CONTROLDUAL OUTPUT (HEAT/COOL) CONTROLDESCRIPTIONThe controller can provide dual output (heat/cool) control with each of thethree

Pagina 116

IB-23C650DUAL OUTPUT CONTROLFigure 27. Dual Output (Heat/Cool) Output TransitionTransitionBandwidth75%Cool Output100%or CoolHighLimit100%or HeatHigh

Pagina 117

IB-23C650ON/OFF CONTROLON/OFF CONTROLDESCRIPTIONThe on/off output calculation diagram is shown in Figure 29. The local set-point adjustment is made u

Pagina 118

IB-23C650ON/OFF CONTROLFigure 29. On/Off Output CalculationProcessOutputSwitchCalcu-latedOutputManualAutoS-1107-265(1)On/OffControlAlgorithmActiveSet

Pagina 119

IB-23C650POSITION PROPORTIONING CONTROLPOSITIONING PROPORTIONING CONTROLDESCRIPTIONPositioning proportioning control permits PID control to be used in

Pagina 120

IB-23C650POSITION PROPORTIONING CONTROLReasonable values for Position Proportioning Deadband and Preact can bedetermined using the following procedure

Pagina 121 - Table 12. Tune Menu

IB-23C650DIAGNOSTICSDIAGNOSTICSINPUT FAILURE AND POWER FAILURE DETECTIONThe fault detection level for volt inputs is determined by the percent of volt

Pagina 122

IB-23C650DIAGNOSTICSconditions using the UP key. Input Failure Messages• [OPEN TC1 (2)] Open Thermocouple 1 (or 2) (upscale burnout)• [HIGH TC1 (2)]

Pagina 123

IB-23C650DIAGNOSTICSThe following messages may indicate a failure of a component. If themessage is temporary, the cause may be some other electrical

Pagina 124

IB-23C650INSTALLATIONFigure 4. RTD Input Connectionst°NoteRTD INPUTt°2-WIRE RTDShield3-WIRE RTDShieldNote: 4-Wire RTD connectedsame as 3-wire RTDwith

Pagina 125

IB-23C650DIAGNOSTICS Problem Possible Cause ActionNo display a. No power to controller.b. Controller not fullyseated in housing.c. Incorrect powerconn

Pagina 126

IB-23C650CALIBRATION DATACALIBRATION DATAINTRODUCTIONThe 2050R base controller (main board) is factory calibrated and does notrequire calibration data

Pagina 127

IB-23C650CALIBRATION DATATable 15. Main/Option Board Calibration (Base Configuration Menu)Step Step DescriptionTopDisplay16Main Board Calibration.UP

Pagina 128

IB-23C650CALIBRATION DATATable 15. Main/Option Board Calibration (Base Configuration Menu)MiddleDisplayBottomDisplayEntry DescriptionCALIBRATNOTE:

Pagina 129 - BASIC OPERATION

IB-23C650CALIBRATION DATATable 15. Main/Option Board Calibration (Base Configuration Menu)Step Step DescriptionTopDisplay16.3Process Input Ma. Resis

Pagina 130

IB-23C650CALIBRATION DATATable 15. Main/Option Board Calibration (Base Configuration Menu)MiddleDisplayBottomDisplayEntry DescriptionMR RATIO xxxxx

Pagina 131 - CONTROL KEYS

IB-23C650CALIBRATION DATATable 15. Main/Option Board Calibration (Base Configuration Menu)Step Step DescriptionTopDisplay17Option Board Calibration.

Pagina 132 - ENGINEERING DISPLAYS

IB-23C650CALIBRATION DATATable 15. Main/Option Board Calibration (Base Configuration Menu)MiddleDisplayBottomDisplayEntry DescriptionCALIBRATNOTE:

Pagina 133 - STATUS DISPLAYS

IB-23C650CALIBRATION DATATable 15. Main/Option Board Calibration (Base Configuration Menu)Step Step DescriptionTopDisplay17.3Input 2 Ma. Resistance

Pagina 134

IB-23C650CALIBRATION DATATable 15. Main/Option Board Calibration (Base Configuration Menu)MiddleDisplayBottomDisplayEntry DescriptionMR RATIO xxxxx

Pagina 135 - Top & Middle

IB-23C650INSTALLATIONFigure 5. 2- Wire Milliampere Input Connections External PowerSupplyMILLIAMPERE INPUT - 2-WIRE TRANSMITTERShield to be left un

Pagina 136 - ALARM INDICATOR

IB-23C650PARTS AND MAINTENANCEPARTS AND MAINTENANCEPARTS AVAILABILITYThe MODCELL 2050 Controller parts available for purchase are:• Termination Assemb

Pagina 137 - . If diagnostic

IB-23C650RECORD OF DATABASEDESCRIPTIONThis section provides tables of the database fields for planning and recordingyour configuration entries via the

Pagina 138 - OPERATION IN AUTOMATIC MODE

IB-23C650Data Base RecordTopDisplayMiddleDisplayBot. Disp.EntryTopDisplayMiddleDisplayBot. Disp.EntryBASE CFG **MENU** * BRD CALIBRATMAIN PWR FREQ DEF

Pagina 139

IB-23C650Data Base RecordTopDisplayMiddleDisplayBot. Disp.EntryTopDisplayMiddleDisplayBot. Disp.EntryRIGHT BAR DI SETPT SEL LISTDEV BAR FULL SCL MA. O

Pagina 140

IB-23C650Data Base RecordTopDisplayMiddleDisplayBot. Disp.EntryTopDisplayMiddleDisplayBot. Disp.EntryRAT BIAS **MENU** SETPT 3 LO LIMITRAT BIAS TYPE S

Pagina 141

IB-23C650100Data Base RecordTopDisplayMiddleDisplayBot. Disp.EntryTopDisplayMiddleDisplayBot. Disp.EntryRAMPSOAK **MENU** SEG * SETUP See BelowRAMPSOA

Pagina 142 - AUTO/MANUAL TRANSFER

IB-23C650Data Base RecordTopDisplayMiddleDisplayBot. Disp.EntryTopDisplayMiddleDisplayBot. Disp.EntryALARMS **MENU** ALARM 4 PRIORITYBEEP ON OCCUR OF

Pagina 144 - OPERATION IN MANUAL

The Company’s policy is one of continuous product improvement and the rightis reserved to modify the information contained

Pagina 145

IB-23C650INSTALLATIONFigure 6. Non 2-Wire Milliampere Input Connections Note: Non 2-Wire Transmitter may also be ungrounded. MILLIAMPERE INPUT - N

Pagina 146

IB-23C650INSTALLATIONFigure 7. Voltage Input Connections VOLT INPUTGROUNDEDShield to be left un-connected at this end.VSource– + GUNGROUNDEDVSource–

Pagina 147

IB-23C650INSTALLATIONFigure 8. Millivolt Input ConnectionsShield to be left uncon-nected at this end.Note: Terminals 12 & 13must be wiredtogether

Pagina 148

IB-23C650INSTALLATIONFigure 9. Digital Input Connections 1.2KTo Micro-processor4.5KSame as#31Note: External devicesinks current. CONTROLLER+5VDIGITA

Pagina 149 - Enabling Digital Inputs

IB-23C650INSTALLATIONPOSITION FEEDBACK (SLIDEWIRE) INPUTFigure 10. Motorized Valve and Slidewire ConnectionsWiperCloseOpenInst.ACPowerAutoFwdRevNote:

Pagina 150

IB-23C650INSTALLATIONOUTPUT SIGNAL CONNECTIONSOutput connections are shown as follows:• mA Outputs - see Figure 11• Voltage Outputs - see Figure 12• R

Pagina 151 - One Digital Input

IB-23C650INSTALLATIONMILLIAMPERE OUTPUTFigure 11. Milliampere Output Connections –+Output LoadMilliampere Output specifications are: Range: 0 to 54

Pagina 152 - CONTROL OUTPUT LIMITING

IB-23C650CONTENTS CONTENTSPageIntroductionFeatures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Description . . . . . . . . .

Pagina 153

IB-23C650INSTALLATIONVOLT OUTPUT (0 to 10 Volts dc)Figure 12. Voltage Output Connections –+Output ReceiverPrecision Dropping Resistor Typical Val

Pagina 154

IB-23C650INSTALLATIONDIGITAL OUTPUTFigure 13. Digital Output Connections+ –OutputLoadExternalPower SupplyCONTROLLERNONCNote: Connections shown are f

Pagina 155 - Alarms with Acknowledgment

IB-23C650INSTALLATIONBlank Page26

Pagina 156 - Alarm Type Messages

IB-23C650SETUPSETUPCAUTIONBe sure the process can be maintained in safe conditions before turning oncontroller power. The controller may not be prope

Pagina 157

IB-23C650SETUPSETUP FUNCTIONSFor ease of use, the firmware has been divided into functional groups. Thefirst group is for daily continuing operation,

Pagina 158

IB-23C650SETUPDISPLAYS **MENU**Displays MenuBASE CFG **MENU**Base Configuration MenuINPUTS **MENU**Inputs MenuDIG INPT **MENU**Digital Inputs MenuMA.

Pagina 159 - MANUAL TUNING

IB-23C650SETUPTable 1. Base ConfigurationStep Step DescriptionTopDisplay1Base Configuration Menu.UP moves to DISPLAYS **MENU**. DN moves to INPUTS *

Pagina 160 - key to set

IB-23C650SETUPTable 1. Base ConfigurationMiddleDisplayBottomDisplayEntry Description**MENU**None.FREQ 60 HERTZ50 HERTZOptimize input line frequency

Pagina 161 - I = P (Minutes)

IB-23C650SETUPTable 1. Base ConfigurationStep Step DescriptionTopDisplay3.2.1(cont’d)Process Calibration Correction. 4 Input 2 Enable. (Requires Op

Pagina 162

IB-23C650SETUPTable 1. Base ConfigurationMiddleDisplayBottomDisplayEntry Description3. Be sure that any length of thermocoupleextension wire or RTD

Pagina 163 - Setup Procedure

IB-23C650CONTENTSCONTENTS (Cont’d)PageEngineering Displays . . . . . . . . . . . . . . . . . . . . . . . . . 126Status Displays . . . . . . . . . . .

Pagina 164

IB-23C650SETUPTable 1. Base ConfigurationStep Step DescriptionTopDisplay4.1.2.1Input 2 Calibration Correction. UP or DN sets correction temperature.

Pagina 165

IB-23C650SETUPTable 1. Base ConfigurationMiddleDisplayBottomDisplayEntry Descriptionxxx.x xx.xWhere xxx.x = input 2 temperature and xx.x= temperatu

Pagina 166

IB-23C650SETUPTable 1. Base ConfigurationStep Step DescriptionTopDisplay5.4Cool Band Output Action. UP or DN selects cool band output action. SCRL

Pagina 167 - Table 13. Autotune Procedure

IB-23C650SETUPTable 1. Base ConfigurationMiddleDisplayBottomDisplayEntry DescriptionACTION DIRECTREVERSE= relay output is open or mA output #2 isMA

Pagina 168 - STEP SIZ (Step 5)

IB-23C650SETUPTable 1. Base ConfigurationStep Step DescriptionTopDisplay5.5.5Repeat Calibration. UP selects YES or DN selects NO. SCRL advances to:

Pagina 169 - Table 13. Autotune Procedure

IB-23C650SETUPTable 1. Base ConfigurationMiddleDisplayBottomDisplayEntry DescriptionCALIBRAT NOYES= Don’t repeat the procedure.= Repeat the calibra

Pagina 170 - to advance to:

IB-23C650SETUPTable 1. Base ConfigurationStep Step DescriptionTopDisplay11Totalizer Enable. UP selects YES or DN selects NO. SCRL advances to Step

Pagina 171

IB-23C650SETUPTable 1. Base ConfigurationMiddleDisplayBottomDisplayEntry DescriptionENABLE NOYES= Don’t allow TOTALIZE **MENU** setup orTOT variabl

Pagina 172

IB-23C650SETUPTable 1. Base ConfigurationStep Step DescriptionTopDisplay16Main Board Calibration Data.UP begins calibration. See Calibration Datasec

Pagina 173

IB-23C650SETUPTable 1. Base ConfigurationMiddleDisplayBottomDisplayEntry DescriptionCALIBRATEntry point for main board calibration. SeeCalibration

Pagina 174

IB-23C650CONTENTSCONTENTS (Cont’d)PageDiagnosticsInput Failure and Power Failure Detection . . . . . . . . . . 201Diagnostic Messages . . . . . . . .

Pagina 175 - RAMP/SOAK OPERATION

IB-23C650SETUPTable 1. Base ConfigurationStep Step DescriptionTopDisplay18.2Configuration has Changed. SCRL advances to Step 19. CONFIG 19 Lock con

Pagina 176

IB-23C650SETUPTable 1. Base ConfigurationMiddleDisplayBottomDisplayEntry DescriptionCHANGEDThis is just a reminder that the instrumentneeds to be r

Pagina 177 - OPERATION IN AUTOMATIC

IB-23C650SETUPTable 2. Input Setup MenuStep Step DescriptionTopDisplay1Inputs Menu.UP moves to BASE CFG **MENU**.DN moves to DIG INPT **MENU**.SCRL t

Pagina 178

IB-23C650SETUPTable 2. Input Setup MenuMiddleDisplayBottomDisplayEntry Description**MENU**None.POINT 0.0.00.000.000= Display units= Display tenths= D

Pagina 179 - CONTROLLING RAMP/SOAK PROFILE

IB-23C650SETUPTable 2. Input Setup MenuStep Step DescriptionTopDisplay3.4Process Input Linearization Type.UP or DN selects type.SCRL to advance to St

Pagina 180

IB-23C650SETUPTable 2. Input Setup MenuMiddleDisplayBottomDisplayEntry DescriptionLIN TYPE NONESQR ROOTUNITS HI xxxx–3000 to 30000 for mV, V, mA, and

Pagina 181 - Ramp/Soak Hold

IB-23C650SETUPTable 2. Input Setup MenuStep Step DescriptionTopDisplay3.6Process Input Engineering Units, Low. UP or DN sets engineering units.SCRL

Pagina 182

IB-23C650SETUPTable 2. Input Setup MenuMiddleDisplayBottomDisplayEntry DescriptionUNITS LO xxxx–3000 to 30000Note: Fixed at 0 when process inputlinea

Pagina 183 - TOTALIZER OPERATION

IB-23C650SETUPTable 2. Input Setup MenuStep Step DescriptionTopDisplay3.10Recovery Option. UP or DN selects option.SCRL to advance to:Step 4 if inpu

Pagina 184 - Totalizer Reset Display

IB-23C650SETUPTable 2. Input Setup MenuMiddleDisplayBottomDisplayEntry DescriptionOPTION MANUALLAST= Makes instrument return to the manualmode after

Pagina 185 - Predetermined Count

IB-23C650CONTENTSILLUSTRATIONS (Cont’d) Figure Page21 Effect of Ratio Adjustment in a Direct Ratio Control System . . . . . . . . . . . . . . . . .

Pagina 186

IB-23C650SETUPTable 2. Input Setup MenuStep Step DescriptionTopDisplay4.5Input 2 Engineering Units, High. UP or DN sets engineering units.SCRL to ad

Pagina 187

IB-23C650SETUPTable 2. Input Setup MenuMiddleDisplayBottomDisplayEntry DescriptionUNITS HI xxxx–3000 to 30000 for mV, V, mA, and slidewire (minimum s

Pagina 188

IB-23C650SETUPTable 2. Input Setup MenuStep Step DescriptionTopDisplay4.7Input 2 Fault Action. UP or DN selects action.SCRL to advance to: Step 4.8

Pagina 189 - RATIO BIAS CONTROL

IB-23C650SETUPTable 2. Input Setup MenuMiddleDisplayBottomDisplayEntry DescriptionACTIONNONELOCALNONEHOLD POSCLSD POSOPEN POSOutput type is NOT Posi

Pagina 190 - Ratio Function

IB-23C650SETUPTable 2. Input Setup MenuStep Step DescriptionTopDisplay5Engineering Units Label. UP to begin label entry.SCRL to advance to Step 6.1.

Pagina 191 - Bias Function

IB-23C650SETUPTable 2. Input Setup MenuMiddleDisplayBottomDisplayEntry DescriptionLABEL xxxWhere x = any of the characters listed underTag Name in th

Pagina 192

IB-23C650SETUPTable 3. Digital Input Setup MenuStep Step DescriptionTopDisplay1Digital Input Menu.UP moves to INPUTS **MENU**.DN moves to MA. OUTP **M

Pagina 193 - A/M RATIO BIAS STATION

IB-23C650SETUPTable 3. Digital Input Setup MenuMiddleDisplayBottomDisplayEntry Description**MENU**None.INPUT 1 None.FUNCTION NONEAUTO/MANALRM ACKTOTAL

Pagina 194

IB-23C650SETUPTable 3. Digital Input Setup MenuStep Step DescriptionTopDisplay2.1.3Manual to Auto Transition Allowed. UP or DN selects YES or NO.SCRL

Pagina 195 - A/M Switching

IB-23C650SETUPTable 3. Digital Input Setup MenuMiddleDisplayBottomDisplayEntry DescriptionALLOWED NOYES= Allows digital input to switch control modeon

Pagina 196

IB-23C650INTRODUCTIONINTRODUCTIONFEATURES• Isolated universal process and remote set-point input• Four internal set-points• No jumpers required to def

Pagina 197 - TIME PROPORTIONING CONTROL

IB-23C650SETUPTable 3. Digital Input Setup MenuStep Step DescriptionTopDisplay2.1.7Totalizer Command Lockout. UP or DN selects YES or NO.SCRL to adva

Pagina 198 - S-1107-41B

IB-23C650SETUPTable 3. Digital Input Setup MenuMiddleDisplayBottomDisplayEntry DescriptionLOCKOUT YESNO= Locks out the front panel totalizercommands i

Pagina 199 - CURRENT PROPORTIONING CONTROL

IB-23C650SETUPTable 3. Digital Input Setup MenuStep Step DescriptionTopDisplay3.1Digital Input 2 Function.UP or DN selects function.SCRL to advance to

Pagina 200

IB-23C650SETUPTable 3. Digital Input Setup MenuMiddleDisplayBottomDisplayEntry DescriptionFUNCTION NONEAUTO/MANALRM ACKTOTALIZERAMPSOAKSETP SELOUTP TR

Pagina 201 - DESCRIPTION

IB-23C650SETUPTable 3. Digital Input Setup MenuStep Step DescriptionTopDisplay3.1.5Ramp/Soak Digital Input 2 Command Lockout. UP or DN selects YES or

Pagina 202 - S-1107-52A

IB-23C650SETUPTable 3. Digital Input Setup MenuMiddleDisplayBottomDisplayEntry DescriptionLOCKOUT YESNO= Locks out the front panel ramp/soakcommands i

Pagina 203 - ON/OFF CONTROL

IB-23C650SETUPTable 3. Digital Input Setup MenuStep Step DescriptionTopDisplay3.1.9Local to Remote Transition Allowed. UP or DN selects YES or NO.SCR

Pagina 204

IB-23C650SETUPTable 3. Digital Input Setup MenuMiddleDisplayBottomDisplayEntry DescriptionALLOWED NOYES= Digital input transition selects any set-poin

Pagina 205

IB-23C650SETUPTable 4. Milliamp Output Setup MenuStep Step DescriptionTopDisplay1Milliamp Output Menu.UP moves to DIG INPT **MENU**.DN moves to RELAYS

Pagina 206

IB-23C650SETUPTable 4. Milliamp Output Setup MenuMiddleDisplayBottomDisplayEntry Description**MENU**None.MA. HIGH xx.x 01.0 to 54.0 mA dcThe current p

Pagina 207 - DIAGNOSTICS

IB-23C650INTRODUCTIONRanging of the RTD and Thermocouple is automatic. The process input isisolated from the rest of the instrument. A 24V dc transm

Pagina 208 - Operational Failure Messages

IB-23C650SETUPTable 4. Milliamp Output Setup MenuStep Step DescriptionTopDisplay9.1Fixed Output Value.UP or DN sets fixed initial power up output valu

Pagina 209 - TROUBLESHOOTING

IB-23C650SETUPTable 4. Milliamp Output Setup MenuMiddleDisplayBottomDisplayEntry DescriptionUP OUTPT xx.x–8.0 to 110.0. Limited by output high and lo

Pagina 210 - Problem Possible Cause Action

IB-23C650SETUPTable 5. Output Relays Setup MenuStep Step DescriptionTopDisplay1Output Relays Menu.UP moves to MA. OUTP **MENU**.DN moves to RAT BIAS *

Pagina 211 - CALIBRATION DATA

IB-23C650SETUPTable 5. Output Relays Setup MenuMiddleDisplayBottomDisplayEntry Description**MENU**None.SETUP None.FUNCTION NONEALARMSTOTALIZERAMPSOAKR

Pagina 212

IB-23C650SETUPTable 5. Output Relays Setup MenuStep Step DescriptionTopDisplay3.1.1Relay B Alarm Trip Action.UP or DN selects alarm combination.SCRL t

Pagina 213

IB-23C650SETUPTable 5. Output Relays Setup MenuMiddleDisplayBottomDisplayEntry DescriptionTRIP ACT 1234•••123415 possible combinations of the four dis

Pagina 214

IB-23C650SETUPTable 6. RS-485 Setup MenuStep Step DescriptionTopDisplay1RS-485 Menu. (requires option board)UP moves to RELAYS **MENU**.DN moves to R

Pagina 215

IB-23C650SETUPTable 6. RS-485 Setup MenuMiddleDisplayBottomDisplayEntry Description**MENU**None.81

Pagina 216

IB-23C650SETUPTable 7. Auto/Manual Ratio Bias Setup MenuStep Step DescriptionTopDisplay1A/M Ratio Bias Menu.UP moves to RELAYS **MENU**.DN moves to TO

Pagina 217

IB-23C650SETUPTable 7. Auto/Manual Ratio Bias Setup MenuMiddleDisplayBottomDisplayEntry Description**MENU**None.TYPE RATIOBIASRAT BIAS= Ratio only sta

Pagina 218

IB-23C650 INTRODUCTION 3 Data Plate

Pagina 219

IB-23C650SETUPTable 7. Auto/Manual Ratio Bias Setup MenuStep Step DescriptionTopDisplay7Ratio Source for Ratio and Bias Type.UP or DN selects source.S

Pagina 220 - MAINTENANCE

IB-23C650SETUPTable 7. Auto/Manual Ratio Bias Setup MenuMiddleDisplayBottomDisplayEntry DescriptionSOURCE LOCALREMOTEInitial value can be set in "

Pagina 221 - RECORD OF DATABASE

IB-23C650SETUPTable 8. Set-Point Setup MenuStep Step DescriptionTopDisplay1Set-Point Menu.UP moves to RELAYS **MENU**.DN moves to RAMPSOAK **MENU** if

Pagina 222

IB-23C650SETUPTable 8. Set-Point Setup MenuMiddleDisplayBottomDisplayEntry Description**MENU**None.None.FIXED NOYES= Allows changes in Displays menu=

Pagina 223

IB-23C650SETUPTable 8. Set-Point Setup MenuStep Step DescriptionTopDisplay3.4Local Set-Point 2 Low Limit.UP or DN sets value.SCRL to advance to Step 3

Pagina 224

IB-23C650SETUPTable 8. Set-Point Setup MenuMiddleDisplayBottomDisplayEntry DescriptionLO LIMIT xxxx–3000 to high limitINIT VAL xxxx Low limit to high

Pagina 225

IB-23C650SETUPTable 8. Set-Point Setup MenuStep Step DescriptionTopDisplay5.2Local Set-Point 4 Fixed.UP or DN selects YES or NO.SCRL to advance to Ste

Pagina 226

IB-23C650SETUPTable 8. Set-Point Setup MenuMiddleDisplayBottomDisplayEntry DescriptionFIXED NOYES= Allows changes in Displays menu= This local set-poi

Pagina 227

IB-23C650SETUPTable 8. Set-Point Setup MenuStep Step DescriptionTopDisplay6.1Input 2 is Missing.This warning will time out in 1 second and return to s

Pagina 228

IB-23C650SETUPTable 8. Set-Point Setup MenuMiddleDisplayBottomDisplayEntry DescriptionMISSING REM SETPNone.UP SETPT xxxx –3000 to 30000, within local