MOD 30ML Functions
DISPLAY INTERFACE BLOCK
Field Mnemonic Valid Values CWR Data Type Attr
Port 3 Noise Counter NOISECTR – WR Count 28
Port 3 Buffer Full Counter BFULLCTR – WR Count 29
Port 3 Communications Error
Counter
CMERRCTR – WR Count 30
Keyboard Error Counter KBERRCTR – WR Count 31
Flash Periods: Slow - Off Counts
SFOFFCNT CWR Long State 32
Flash Periods: Slow - On Counts
SFONCNT CWR Long State 33
Flash Periods: Fast - Off Counts
FFOFFCNT CWR Long State 34
Flash Periods: Fast - On Counts
FFONCNT CWR Long State 35
Flash Periods: Activity - Off
Counts
ACOFFCNT CWR Long State 36
Flash Periods: Activity - On
Counts
ACONCNT . CWR Long State 37
Entry Timeout
ENTRTIME NONE (65535), CWR Count 38
Date Format
DATEFMT US (0), or EURO (1). CWR Discrete 39
Shutdown Instrument on
Faceplate Comm Failure
SHUTFAIL NO (0), YES (1). CWR Discrete 40
Remote Display Number Input
REMDISP CWR Count 60
Block Type
DIF This is the display interface block type.
00 Block Version (VERSION) ................................................................................................ – – R
The display interface block is at version 1.
01 Block Length (BLKLEN) .................................................................................................... – – R
Number of database bytes taken by the block. Always an even number.
02 State (STATE) .................................................................................................................... CWR
Block state is always RUN. See IB-23G600 (Logic Book 1) Section 2.4.1, State Changes
for additional information on block states.
RUN 0 Normal Operation. Block is always executed.
03 Bad Inputs Accepted (BADINP) .......................................................................................CWR
See IB-23G600 (Logic Book 1) Section 2.3.2, Data Quality for additional information.
Rejected 0 Block checks data quality on its inputs and, if it is BAD, no action will be
taken on the input and display selection will revert to the TAG key.
Accepted 1 Block runs its algorithm without a check on input quality.
04 Diagnostic Group (SUPPGRP)......................................................................................... CWR
The diagnostic error reported by this block can be grouped for System Event block control of
its reporting. The selections are:
NONE No group assigned.
1 to 7 Defines the diagnostic group number for the diagnostic suppression group
controlled by the System Event block.