escent process operating
level.
(Setpoint)
Programmer
Mode
An operating mode of the
characterizer that allows 13
time intervals to be defined
with ProG-chr parameter con-
stants K1-K13. Values en-
tered into chr parameter
constants K14-K26 are the
ramp values for each of the
time intervals.
Single
Station
Cascade
Control
A control strategy whereby
the controller response to
process changes is enhanced
by using two loops for an oth-
erwise single loop applica-
tion. The primary loop, which
calculates a deviation output
from a slower responding
process provides the input
setpoint to a secondary loop.
The secondary loop calcu-
lates a deviation output from
the primary loop setpoint in-
put and a process variable
from a faster responding
process to alter the final con-
trol element position. This in
turn affects the slower re-
sponding process and ulti-
mately the primary loop
setpoint output. Cascade
control is much tighter than
single loop control, as the sin-
gle loop would calculate a de-
viation only from a predefined
setpoint and a process vari-
able from the slower respond-
ing process. This control
strategy is implemented in the
53SL6000 controller with the
factory default settings and
by selecting cASc for the
ProG-cS-SchM parameter.
Single
Station
Override
Control
A control strategy whereby
two loops, primary and limit-
ing, operate interdependently
to control a final single ele-
ment. With this strategy, nei-
ther variable may exceed a
safe limit. The primary loop
is in control unless its output
tries to exceed the high or low
limit defined by the limiting
loop. If the high limit is ex-
ceeded, the controller will se-
lect the lower of the two
output values (low override).
If the low limit is exceeded,
the controller will select the
higher of the two output val-
ues (high override). The low
limit control strategy is imple-
mented with the factory de-
fault settings and by selecting
the L.LiM for the ProG-cS-
SchM parameter. The high
limit control strategy is imple-
mented with the factory de-
fault settings and by selecting
the h.LiM for the ProG-cS-
SchM parameter.
Switch
A symbol used in the control
scheme setpoint-deviation,
PID, and output path illustra-
tions that physically repre-
sents a control signal or
possible control scheme pa-
rameter selection choices.
Third
Order
Polynomial
Mode
An operating mode of the
characterizer that provides a
monotonically increasing in-
dexing capability to five third
order polynomial equations
that represent five adjacent
segments. Each segment
represents a defined control-
ler output. Equation selection
is specified with the ProG-
chr-K1 through K6 parame-
ters and values entered into
ProG-chr-K7 through K26 pa-
rameter constants are the co-
efficients A through D of the
five equations.
Tuning
The iterative procedure of
finding the optimal controller
PID (proportional, integral,
and derivative) values as re-
quired for the process under
control.
Twelve
Segment
Appendix A. Glossary 53SL6000 Instruction Manual
A-5