MODCELL Multiloop Processor Installation
Product Description, Installation and Wiring for
2002N Model C and Associated Hardware
Vista de pagina 0
1 2 3 4 5 6 ... 81 82

Indice de contenidos

Pagina 1 - Installation

MODCELL™ Multiloop Processor Installation Product Description, Installation and Wiring for 2002N Model C and Associated Hardware

Pagina 2 - MicroMod Automation, Inc

MODCELL Multiloop ProcessorPRODUCT DESCRIPTION1.3.3 2001P Logic Control Identity ModuleThe identity module gives the processor a specific level of pro

Pagina 3 - CONTENTS

MODCELL Multiloop ProcessorPRODUCT DESCRIPTION1.3.4 2004P Advanced Control Identity ModuleThe identity module gives the processor a specific level of

Pagina 4

MODCELL Multiloop ProcessorPRODUCT DESCRIPTION1.4 I/O MODULESThe descriptions included in this section give a brief overview of the functions andfeatu

Pagina 5 - ILLUSTRATIONS

MODCELL Multiloop ProcessorPRODUCT DESCRIPTION1.4.2 2002A Current Input ModuleThe current input module is identical to the voltage input module except

Pagina 6

MODCELL Multiloop ProcessorPRODUCT DESCRIPTION1.4.4 2013A Thermocouple Input Module (with upscale burnout detection)The thermocouple input module is i

Pagina 7 - 1 - PRODUCT DESCRIPTION

MODCELL Multiloop ProcessorPRODUCT DESCRIPTION1.4.6 2004A Solid-State Relay Input ModuleThe Solid-State Relay Input module provides the necessary inte

Pagina 8

MODCELL Multiloop ProcessorPRODUCT DESCRIPTION1.4.8 2006A Nonisolated Digital Input ModuleThe Nonisolated Digital Input Module is primarily intended f

Pagina 9 - 1.3 BASIC HARDWARE

MODCELL Multiloop ProcessorPRODUCT DESCRIPTION1.4.10 2011A Mechanical Relay Output ModuleThe Mechanical Relay Output Module may have dual SPST relays

Pagina 10

MODCELL Multiloop ProcessorPRODUCT DESCRIPTION1.4.12 2020N Remote I/O Interface ModuleRemote Input and Output Modules expand the I/O capability of a M

Pagina 11 - 1.3.5 2010P Memory Module

MODCELL Multiloop ProcessorPRODUCT DESCRIPTION1.5.2 2032N RS-485 Communication Module for Modbus (2-Wire)This RS-485 Communication module is a 75LBC17

Pagina 12 - 1.4 I/O MODULES

MicroMod Automation, Inc. The Company MicroMod Automation is dedicated to improving customer efficiency by providing the most cost-effective, applic

Pagina 13

MODCELL Multiloop ProcessorPRODUCT DESCRIPTION1.5.4 2034N RS-485 Communication Module for Modbus (4-Wire)This RS-485 Communication module is a pair of

Pagina 14

MODCELL Multiloop ProcessorPRODUCT DESCRIPTION1.6 RELATED DOCUMENTATIONReference information on the data base structure and configuration parameters f

Pagina 15

MODCELL Multiloop ProcessorPRODUCT DESCRIPTION16

Pagina 16

MODCELL Multiloop ProcessorMECHANICAL INSTALLATION2 - MECHANICAL INSTALLATION2.1 GENERALRead these instructions thoroughly before starting installatio

Pagina 17 - 1.4.11 2009A RTD Input Module

MODCELL Multiloop ProcessorMECHANICAL INSTALLATIONTable 2-1. Module Types and Suggested LocationsBlockTypeModule TypeModule Location1 to 16 17 to 32V

Pagina 18 - 1.5 COMMUNICATION MODULES

MODCELL Multiloop ProcessorMECHANICAL INSTALLATION2.3.2 Current ConsumptionThe Model C multiloop processor has the capacity to handle any mix of I/O t

Pagina 19

MODCELL Multiloop ProcessorMECHANICAL INSTALLATION2.4 MOUNTINGThe instrument must be installed in an approved enclosure or installed in a meansaccepta

Pagina 20 - 1.5.5 2030F ICN Terminator

MODCELL Multiloop ProcessorMECHANICAL INSTALLATION2.4.1 2002N Multiloop Processor - Flush MountThe flush mount processor can be mounted directly

Pagina 21 - 1.6 RELATED DOCUMENTATION

MODCELL Multiloop ProcessorMECHANICAL INSTALLATION22

Pagina 22 - MODCELL Multiloop Processor

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONS3 - ELECTRICAL CONNECTIONS3.1 TERMINAL IDENTIFICATIONThe power wiring connections and input/output (I

Pagina 23 - 2 - MECHANICAL INSTALLATION

MODCELL Multiloop ProcessorCONTENTSCONTENTSPage1 - PRODUCT DESCRIPTION1.1 OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 24

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONS2030FZ00002AICN TerminatorRed Pin = 24VSlot N / Slot N+1Figure 3-1. Terminations for 2002N24

Pagina 25 - 2.3.2 Current Consumption

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONS3.3 POWER CONNECTIONSWARNINGAvoid electrical shock. AC power wiring must not be connected atthe distr

Pagina 26 - WARNING

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONS3.4.2 Shield GroundThe shield terminals, Figure 3-1, are only connected to one another; they are noti

Pagina 27

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONS3.4.5 Noise Prevention MeasuresPrimary power circuit distribution system:• Ideally, each microprocess

Pagina 28 - MECHANICAL INSTALLATION

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONS• Any connection made to provide a noise ground should be kept as short as possibleusing the largest

Pagina 29 - 3 - ELECTRICAL CONNECTIONS

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONSFigure 3- 2. Typical Input Circuit for 2013A Thermocouple Input ModuleThermocouple(B,E,J,K,N,R,S,T)+V

Pagina 30 - ELECTRICAL CONNECTIONS

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONS3.5.2 2004A SSR Input (DIM)Make Solid-State Relay (SSR) connections as shown in Figure 3-4. These in

Pagina 31 - 3.4.1 Chassis Ground

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONSS-3031-16Figure 3- 3. Typical Input Circuit for 2004A Solid State Input ModuleS11S10–+L2 or –L1 or

Pagina 32 - 3.4.4 Electrical Noise

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONS32

Pagina 33

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONS3.5.3 2006A Nonisolated Digital Input (DIM)Make nonisolated digital input connections to terminal blo

Pagina 34

MODCELL Multiloop ProcessorCONTENTSCONTENTS (Cont’d)Page3.4.2 Shield Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 35

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONS3.5.4 2002A and 2012A Current Inputs (VCIM)Make current input connections to terminal block as shown

Pagina 36 - 3.5.2 2004A SSR Input (DIM)

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONSS-3031-18Figure 3- 5. Typical Input Circuits for 2002A Current Input Module and 2012A Current Input M

Pagina 37 - S-3031-16

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONS3.5.5 2001A Voltage Input (VCIM)Make volt or millivolt connections to terminal block as shown in Figu

Pagina 38

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONS3.5.6 2009A RTD Input (RIM, WRIM)Make resistance input connections to terminal block as shown in Figu

Pagina 39 - S-3031-17

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONSS-3031-29Figure 3- 7. Typical Input Circuit for 2009A RTD Input ModuleINCS201421RefRef3-WireRTDS19A/

Pagina 40

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONS3.6 OUTPUT CONNECTIONSThis section describes the process output connections for the following output

Pagina 41 - S-3031-18

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONS3.6.2 2005A SSR Output (DOM)Recommended connections to a customer relay are shown in Figure 3-10. Ma

Pagina 42

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONSS-3031-22Figure 3-1 0. Typical Output Circuits for 2005A Solid State Relay Output ModuleS8S7L2–+BASE

Pagina 43

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONS3.6.3 2007A Nonisolated Digital Output (DOM)Make nonisolated digital output connections as shown in F

Pagina 44 - S-3031-29

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONS3.6.4 2011A Dual Mechanical Relay Outputs (DDOM)Make mechanical relay output connections as shown in

Pagina 45

MODCELL Multiloop ProcessorCONTENTSILLUSTRATIONSPage1-1 Modcell 2002N Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 46 - 3.6.2 2005A SSR Output (DOM)

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONS3.6.5 2011A Form C Mechanical Relay Outputs (WDOM)Make mechanical relay output connections as shown i

Pagina 47 - S-3031-22

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONS3.7 2020N REMOTE I/O INTERFACE CONNECTIONS (RIO)Make remote I/O interface connections as shown in Fig

Pagina 48

MODCELL Multiloop ProcessorELECTRICAL CONNECTIONSTable 3-3. Supported Remote I/O ModulesModule DescriptionDigital Input Modules . . . . . .ICSI 08 D1

Pagina 49

MODCELL Multiloop ProcessorCOMMUNICATIONS CONNECTIONS4 - COMMUNICATIONS CONNECTIONS4.1 ICN CONNECTIONSA typical Instrument Communications Network (ICN

Pagina 50

MODCELL Multiloop ProcessorCOMMUNICATIONS CONNECTIONSR29, R30 and R31 on any single 1723F Field Input Board (see MOD 30 installationinstructions) sinc

Pagina 51

MODCELL Multiloop ProcessorCOMMUNICATIONS CONNECTIONS4.2 MODBUS NETWORK CONNECTIONS4.2.1 GeneralNumerous Modbus network connection arrangements are po

Pagina 52

MODCELL Multiloop ProcessorCOMMUNICATIONS CONNECTIONS4.2.2 2033N RS-232 Communication for ModbusThe 2033N RS-232 Communication module is a driver/rec

Pagina 53 - 4.1.3 Termination

MODCELL Multiloop ProcessorCOMMUNICATIONS CONNECTIONSFigure 4-2. Typical Modbus Network Connections for 2033N RS-232 Communication ModuleIsolatedComm

Pagina 54

MODCELL Multiloop ProcessorCOMMUNICATIONS CONNECTIONS4.2.3 2032N RS-485 2-Wire Communication for ModbusThe 2032N, Model C RS-485 Communication module

Pagina 55 - 4.2.1 General

MODCELL Multiloop ProcessorCOMMUNICATIONS CONNECTIONSFigure 4-3. Typical Modbus Connections for 2032N RS-485, 2-Wire Module used as a Slave+5VdcPerso

Pagina 56

MODCELL Multiloop ProcessorCONTENTSiv

Pagina 57

MODCELL Multiloop ProcessorCOMMUNICATIONS CONNECTIONSFigure 4-4. Typical Modbus Connections for 2032N RS-485, 2-Wire Module used as a MasterBASE INST

Pagina 58

MODCELL Multiloop ProcessorCOMMUNICATIONS CONNECTIONS4.2.4 2034N RS-485 4-Wire Communication for ModbusThe 2034N RS-485 Communication module, Figure

Pagina 59

MODCELL Multiloop ProcessorCOMMUNICATIONS CONNECTIONSFigure 4-5. Simplified Diagram, 2034N RS-485, 4-Wire Module2034N RS-485 MODULEDATAPLCCSELCLKGND+

Pagina 60

MODCELL Multiloop ProcessorCOMMUNICATIONS CONNECTIONSFigure 4-6. Typical Modbus Connections for 2034N RS-485, 4-Wire Module used as a SlaveIsolated +

Pagina 61

MODCELL Multiloop ProcessorCOMMUNICATIONS CONNECTIONSFigure 4-7. Typical Modbus Connections for 2034N RS-485, 4-Wire Module used as a MasterIsolated

Pagina 62

MODCELL Multiloop ProcessorCOMMUNICATIONS CONNECTIONSFigure 4-8. Typical Modbus Connections for a 4-Wire Master with 2-Wire SlavesIsolated +5Vdc2034N

Pagina 63

MODCELL Multiloop ProcessorCOMMUNICATIONS CONNECTIONS60

Pagina 64

MODCELL Multiloop ProcessorGETTING STARTED5 - GETTING STARTED5.1 INSTALLATION REQUIREMENTSThe section is intended to get you to the point where your i

Pagina 65

MODCELL Multiloop ProcessorGETTING STARTED11. If necessary, change to the correct instrument version icon and then place andconfigure an ICN or MSC bl

Pagina 66 - COMMUNICATIONS CONNECTIONS

MODCELL Multiloop ProcessorGETTING STARTEDcompatible, has valid checksums, no ICN or comm port mismatch), the 'downloadon warm start' attrib

Pagina 67 - 5 - GETTING STARTED

MODCELL Multiloop ProcessorPRODUCT DESCRIPTION1 - PRODUCT DESCRIPTION1.1 OVERVIEWThe MODCELL Multiloop Processor is a microprocessor-based control uni

Pagina 68 - 5.3 USING THE MEMORY MODULE

MODCELL Multiloop ProcessorGETTING STARTED64

Pagina 69 - 5.5 SERVICE/MANUAL SWITCH

MODCELL Multiloop ProcessorAPPENDIX A - PLANNING FORMSAPPENDIX APLANNING FORMSA.1 GENERALThe forms included in this appendix may be copied as necessar

Pagina 70 - GETTING STARTED

MODCELL Multiloop ProcessorAPPENDIX A - PLANNING FORMSI/O MODULE CURRENT CONSUMPTION PLANNING FORM FOR CONTROLLER NUMBER ____Catalog No. DescriptionMa

Pagina 71 - PLANNING FORMS

MODCELL Multiloop ProcessorAPPENDIX A - PLANNING FORMSModule Locations for Controller Number _____No. Module No. Module No. Module No. Module No. Modu

Pagina 72

MODCELL Multiloop ProcessorAPPENDIX A - PLANNING FORMS2002N WIRING PLANNING FORM - FLUSHMOUNTCold JunctionSensor Location_______Wiring Connections for

Pagina 73

MODCELL Multiloop ProcessorAPPENDIX B - SUMMARY OF HARDWARE DIFFERENCESAPPENDIX B - SUMMARY OF HARDWARE DIFFERENCESB.1 GENERALThis document is written

Pagina 74

MODCELL Multiloop ProcessorAPPENDIX B - SUMMARY OF HARDWARE DIFFERENCESAt least one cold junction compensation input is recommended for each controlle

Pagina 75 - B.1 GENERAL

MODCELL Multiloop ProcessorAPPENDIX B - SUMMARY OF HARDWARE DIFFERENCESB.6 MODEL A ICN COMMUNICATION MODULEThe Model A ICN module has no 24V dc supply

Pagina 76

MODCELL Multiloop ProcessorAPPENDIX C - MAINTENANCEAPPENDIX C - MAINTENANCEC.1 MAINTENANCECAUTION. Disconnect power before servicing.Remove dust from

Pagina 77 - S-3031-26(1)

MODCELL Flushmount Controller Instruction NoticeApproved Modules for Class I, Division 2 Hazardous LocationsOnly the following modules may be used in

Pagina 78

MODCELL Multiloop ProcessorPRODUCT DESCRIPTIONThe 2002N Processor is packaged into a flush mount form for rack or panel mounting asshown in Figure 1-2

Pagina 81

The Company’s policy is one of continuous product improvement and the right is reserved to modify the information

Pagina 82

MODCELL Multiloop ProcessorPRODUCT DESCRIPTION1.3 BASIC HARDWAREThe descriptions included in this section give a brief overview of the functions andfe

Comentarios a estos manuales